HomeProductSolar InverterUS LV Hybrid InverterSolis InverterSolis S6-EH3P(30-60)K-NV-YD-H-US – 30kW-60kW Commercial Hybrid Inverter (480V)

Solis S6-EH3P(30-60)K-NV-YD-H-US – 30kW-60kW Commercial Hybrid Inverter (480V)

Solis S6 30kW three phase hybrid inverter. 120/240V output, 150-800V HV battery, 1000V PV input, 3 MPPT, 40A per tracker. TYPE 4X outdoor rated. UL1741. For commercial solar storage.

Rated Power 30kW / 40kW / 50kW / 60kW
Battery 150-800V HV, 70A × 2 ports    
PV Input   1000V Max, 3-4 MPPT, 40A per tracker
AC Output 480V Three Phase (3/N/PE)    
Ingress Protection  TYPE 4X (IP66) Outdoor Rated  
Parallel Capability Up to 6 units (360kW max)

Description

Power Your Commercial Facility with True Energy Independence

Features

⚡ 30-60kW Power Range


🔋 High Voltage Battery (150-800V)


🛡️ TYPE 4X (IP66) Outdoor Rated


☀️ 1000V PV Input – 4 MPPT


🔗 Parallel up to 6 Units


⚡ UPS-Level <10ms Transfer


Technical Data

Parameter 30K 40K 50K 60K
Rated Power (Grid / Backup) 30 kW 40 kW 50 kW 60 kW
Peak Surge 48 kW (160% / 2s) 64 kW (160% / 2s) 80 kW (160% / 2s) 96 kW (160% / 2s)
AC Output (Backup) 480V Three Phase (3/N/PE
Back-up Switch Time <10 ms (UPS level
Battery Voltage Range 150 – 800 VDC (High Voltage)
Battery Ports / Current 2 ports × 70A (33kW each)
Max Battery Power 33kW (single) / 66kW (dual)
Max PV Input Power 60 kW 80 kW 100 kW 120 kW
Max PV Input Voltage 1000 VDC
MPPT Voltage Range 150 – 850 VDC}
MPPT / Strings 3 MPPT / 6 strings 4 MPPT / 8 strings
Max PV Input Current per MPPT 42 A 40 A
Ingress Protection TYPE 4X (IP66) – Outdoor Rated
Dimensions (W×H×D) 560 × 1050 × 346.5 mm (22.0 × 41.3 × 13.6 in
Weight 88.8 – 90 kg (195.8 – 198.4 lbs
Operating Temperature -25°C to +60°C (-13°F to 140°F)
Max Efficiency 97.90%
Communication RS485, CAN, Ethernet, Bluetooth
Parallel Capability Up to 6 units (180kW to 360kW total
Certifications UL 1741, IEEE 1547, CA Rule 21, FCC, TYPE 4X
Warranty 5 years (extendable to 10-20 years)

Elemental Composition

Projects

Download

FAQs

  • Q

    What AC output voltage does this inverter support for South American grids?

    A

    The standard NV model is factory-configured for 480V/60Hz, which is the industrial standard in the US and parts of Colombia (e.g., Bogotá) . However, South America has a mix of voltage standards. For other markets: Chile: Requires 380V/50Hz. Argentina: Requires 380V/50Hz. Brazil: Requires 380V/60Hz. Recommendation: For projects requiring 380V (common in LATAM commercial sites), Solis offers dedicated high-voltage models (often with "H" in the suffix) or variations of the S6-EH3P series programmed for 380V. Do not assume the 480V unit will work for 380V grids; please confirm the "Rated Output Voltage" spec for your specific territory before ordering

  • Q

    Does the inverter comply with local grid interconnection standards in South America (e.g., Brazil, Chile, Argentina)?

    A

    The inverter comes pre-loaded with IEEE 1547-2018, which is the primary standard for the US. While many South American countries base their technical requirements on IEEE 1547, they often impose specific modifications. Brazil (PRODIST): Requires specific anti-islanding and reactive power control. The inverter can be configured, but must be verified against local utility modules. Chile (NCRE): Requires support for Zero Export and specific frequency-watt responses. Argentina: Similar to IEEE 1547 but often requires specific metering (CAMMESA).

  • Q

    Will the inverter's power output derate at high altitudes (e.g., Bogotá, Quito, La Paz)?

    A

    Yes. This inverter is certified for operation up to 3,000m (9,842 ft) per UL standards . However, air density decreases above 2,000m, reducing cooling efficiency. Derating Guidelines: 0 – 2,000m: 100% of rated power (e.g., 60 kW). 2,000 – 3,000m: 1% power derate per 100m (approx 90% power at 3,000m). >3,000m: Significant derating applies; contact engineering for verification. For installations in the Andean region (e.g., Bogotá at 2,640m), you must oversize the inverter or de-rate the capacity in your energy yield simulations.

WhatsApp

Leave a message!

Leave a message!